Parametric Studies for Combined Convective and Conductive Heat Transfer for YASA Axial Flux Permanent Magnet Synchronous Machines
In this paper, the effect of some geometrical parameters on the steady state average temperature of the stator core, the winding and the permanent magnets of the yokeless and segmented armature (YASA) axial flux permanent magnet 5.25 synchronous machine (AFPMSM) is studied.The geometrical parameters selected for the study are the air gap length, th